#Profibus_DP ; PrmText = 1 TEXT(0) = "MSB-LSB" TEXT(1) = "LSB-MSB" EndPrmText PrmText = 2 TEXT(0) = "Disable (X)" TEXT(1) = "Enable (O)" EndPrmText ExtUserPrmData = 1 "Data Word Format" Bit(0) 0 0 - 1; Prm_Text_Ref = 1 EndExtUserPrmData ExtUserPrmData = 2 "Config Data Update?" Bit(1) 0 0 - 1; Prm_Text_Ref = 2 EndExtUserPrmData GSD_Revision = 1 Vendor_Name = "LS Industrial Systems Co., Ltd." Model_Name = "LSLV-G100 Series Slave 1.0" Revision = "Version 1.00" Ident_Number = 0x0A6C Protocol_Ident = 0 Station_Type = 0 Hardware_Release = "Version 1.00" Software_Release = "Version 1.00" Implementation_Type = "VPC3" 9.6_supp = 1 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Auto_Baud_supp = 1 Set_Slave_Add_supp = 0 Min_Slave_Intervall = 5 Modular_Station = 1 Max_Module = 2 Max_Input_Len = 32 Max_Output_Len = 32 Max_Data_Len = 64 Max_Diag_Data_Len = 32 Slave_Family = 1 ;Drive ;Bitmap_Device = "LSISINVR" ;Bitmap_Diag = "LSISINVD" ;Bitmap_SF = "LSISINVS" ; User Parameter Setting User_Prm_Data_Len=5 User_Prm_Data = 0x00,0x00,0x00,0x00,0x00 Ext_User_Prm_Data_Const(0)=0x00,0x00,0x00,0x00,0x00 Ext_User_Prm_Data_Ref(0) = 1 Ext_User_Prm_Data_Ref(0) = 2 ; Extended Diagnostic Unit_Diag_Bit(0) = "Cannot Connect" Unit_Diag_Bit(8) = "H/W Diag Trip" Unit_Diag_Bit(9) = "Latch Type Trip" Unit_Diag_Bit(10) = "Level Type Trip" Unit_Diag_Bit(11) = "Warning" Module = "blank space (0x00)" 0x00 EndModule ;************************************************************************* ;*** input word with consistence *** ;************************************************************************* Module = "1 Word Status Input Data" 0xD0 EndModule Module = "2 Word Status Input Data" 0xD1 EndModule Module = "3 Word Status Input Data" 0xD2 EndModule Module = "4 Word Status Input Data" 0xD3 EndModule Module = "5 Word Status Input Data" 0xD4 EndModule Module = "6 Word Status Input Data" 0xD5 EndModule Module = "7 Word Status Input Data" 0xD6 EndModule Module = "8 Word Status Input Data" 0xD7 EndModule Module = "9 Word Status Input Data" 0xD8 EndModule Module = "10 Word Status Input Data" 0xD9 EndModule Module = "11 Word Status Input Data" 0xDA EndModule Module = "12 Word Status Input Data" 0xDB EndModule Module = "13 Word Status Input Data" 0xDC EndModule Module = "14 Word Status Input Data" 0xDD EndModule Module = "15 Word Status Input Data" 0xDE EndModule Module = "16 Word Status Input Data" 0xDF EndModule ;************************************************************************* ;*** output word with consistence *** ;************************************************************************* Module = "1 Word Control Output Data" 0xE0 EndModule Module = "2 Word Control Output Data" 0xE1 EndModule Module = "3 Word Control Output Data" 0xE2 EndModule Module = "4 Word Control Output Data" 0xE3 EndModule Module = "5 Word Control Output Data" 0xE4 EndModule Module = "6 Word Control Output Data" 0xE5 EndModule Module = "7 Word Control Output Data" 0xE6 EndModule Module = "8 Word Control Output Data" 0xE7 EndModule Module = "9 Word Control Output Data" 0xE8 EndModule Module = "10 Word Control Output Data" 0xE9 EndModule Module = "11 Word Control Output Data" 0xEA EndModule Module = "12 Word Control Output Data" 0xEB EndModule Module = "13 Word Control Output Data" 0xEC EndModule Module = "14 Word Control Output Data" 0xED EndModule Module = "15 Word Control Output Data" 0xEE EndModule Module = "16 Word Control Output Data" 0xEF EndModule